VizieR

CfA VizieR . ADAC VizieR . Cambridge (UK) VizieR . IUCAA VizieR . INASAN VizieR .

Catalog

Looking for catalogs ..
  
J/A+A/535/A117
  Low-charge ions charge transfer rate coeff. (Sterling+, 2011)
Post annotation
  
1.J/A+A/535/A117/ratesFinal-state resolved charge transfer recombination rate coefficients (cm3/s) for the reactions Xq++H ⟶ X(q–1)++H++δE (table4) and X0+H+ ⟶ X++H+δE (table5) (168 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortColumn  Constraint Explain   (UCD)
  recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  El (char) Projectile element (Ge Se Br Kr Rb Xe) (phys.atmol.element)
  ion   [0/5] Ionisation state (phys.atmol.ionStage)
  Tar (char) Target, either H (hygrogen atom) for ionized projectile, or p (proton or H+) for neutral projectile (phys.atmol.element)
  ExitC (char) Exit channel (phys.atmol.configuration)
  a(0.1) cm3/s Rate coefficient α over T=100K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(0.2) cm3/s Rate coefficient α over T=200K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(0.4) cm3/s Rate coefficient α over T=400K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(0.6) cm3/s Rate coefficient α over T=600K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(0.8) cm3/s Rate coefficient α over T=800K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(1.0) cm3/s Rate coefficient α over T=1000K (Note 1)   (arith.rate;phys.atmol.transProb)

ALL cols
    
 (i)indexed column
  a(1.2) cm3/s Rate coefficient α over T=2000K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(1.4) cm3/s Rate coefficient α over T=4000K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(1.6) cm3/s Rate coefficient α over T=6000K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(1.8) cm3/s Rate coefficient α over T=8000K (Note 1)   (arith.rate;phys.atmol.transProb)
  a(10.) cm3/s Rate coefficient α over T=10kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(20.) cm3/s Rate coefficient α over T=20kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(40.) cm3/s Rate coefficient α over T=40kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(60.) cm3/s Rate coefficient α over T=60kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(80.) cm3/s Rate coefficient α over T=80kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(100) cm3/s Rate coefficient α over T=100kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(200) cm3/s Rate coefficient α over T=200kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(400) cm3/s Rate coefficient α over T=400kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(600) cm3/s Rate coefficient α over T=600kK (Note 1)   (arith.rate;phys.atmol.transProb)
  a(800) cm3/s Rate coefficient α over T=800kK (Note 1)   (arith.rate;phys.atmol.transProb)

ALL cols
    
 (i)indexed column
Adapt form
Display your selection only Reset to default columns
usage  Display UCD1+    UCD1  


The following problems were encountered in this VizieR run:
**** -bg is an obsolete option
**** -bg is an obsolete option
**** -bg is an obsolete option
If you can't find a solution, report to CDS and insert into your message the following details:

.errorfile=/tmp/VR1917929.err (2024-05-11T21:33:06)
-2
-source=J/A+A/535/A117
-ref=VIZ663fe4121d43e9
elapse time 0