- Check that the central hub is opened (STSA), and that the table is in
position (RECEIVER user).
- If both are correct, it means the pointing is bad. Check the antenna
time (UT program on the POINTING micro).
- If bad, reset it using the set_time program on
the POINTING micro.
- Reload the pointing constants (by a SETOBSERVE
command), and check the pointing.
- If still bad, reinitialize the antenna, and check the pointing.